3Menu Setting
4Purpose
When alarm input from Channel 2 anytime, the alarm output Channel 1 was triggered and the Buzzer sound; The cameras
CH3 start recording simultaneity; 30 seconds after the alarm input is over, the system stop alarm output and all the relative
operation.
ALARM
CH 02
TYPE NORMAL OPEN
No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUT
REC ●○●○○○○○○○○○○○○○
SLOT1 00002400   ON
SLOT2 00002400   OFF
PRE-RECORDE OFF
DELAY 30SEC
TIP OFF
DEFAULT SAVE   CANCEL
Alarm input from CH2 (Total 16 channel alarm input for choose)
Normal open port
Alarm output from CH1 (Be able to double choose according to
the needs, it means 1 alarm input trigger several alarm output)
Startup alarm recording (Be able to double choose according to
the needs, two period a day for choose)
Pre-record: Choose OFF means not to save the monitoring image
before alarming
Delay: Lengthen the recording time after receiving alarm signals
Tip: Choose OFF means no alarm notification in the screen
Choose SAVE to save all the settings