17
Exam1: Infrared alarm sensor (Inside power and NC) and Alarm light output (please see PIC 1)
1 Connect the sensor(NC) to the DVR alarm input(e.g.: connect to port 1)
2 Connect the ‘+’of the alarm light to the ‘+’of the outside power, and ‘
- to the alarm output of the DVR(e.g.: connect to
OUT2); Connect the cathode of the power to another port of OUT2
3Menu Setting
ALARM
CH 0
TYPE NORMAL CLOSE
No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUT
REC ●○●○○○○○○○○○○○○○
SLOT1 08002400   ON
SLOT2 00002400   OFF
PRE-RECORDE ON
DELAY 30SEC
TIP OFF
DEFAULT SAVE   CANCEL
Alarm input from CH1 (Total 16 channel alarm input for choose)
Normal close port
Alarm output from CH2 (Be able to double choose according to the
needs, it means 1 alarm input trigger several alarm output)
Startup alarm recording (Be able to double choose according to the
needs, two period a day for choose)
Pre-record: Choose On means to save the monitoring image about
5SEC before alarming
Delay: Lengthen the recording time after receiving alarm signals
Tip: Choose ON means to pop up alarm notification in the screen
Choose SAVE to save all the settings